Natural Gas Input Min. 13,000BTU  Max. 199,000BTU 
LPG Input Min. 13,000BTU  Max. 199,000BTU 
Gas Connection 3/4" NPT   
Water Connection 3/4" NPT   
Condensate Water Drain 1/2" NPT   
Natural Gas Pressure Inlet Min. 5.0"WC  Max 10.5"WC 
LP Gas Pressure Inlet Min. 8.0"WC  Max. 14.0"WC 
Weight DV = 73lbs.  OS = 70lbs. 
Dimensions 25.6" x 18.5" x 12.4"   
Ignition Electronic Ignition   
Electrical Supply AC 120V (60 Hz)   
Water Pressure Min. 15psi  Max. 150psi 
T-H2-DV Manifold Pressure Natural: 3.2"WC  Propane:5.5"WC 
T-H2-OS Manifold Pressure Natural: 2.7"WC  Propane:4.6"WC 
TM-RE30
Temperature Remote Control
The TM-RE30 Temperature Remote Controller allows the output temperature to be adjusted beyond the factory settings, and works as a diagnostic tool for error codes.
TH-NT01
Neutralizer
Helps to neutralize the excess acidic condensate.
9007605005
Isolation Valves & Pressure Relief Valve
Isolation valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi.
9007604005
Lead free Isolation Valves & Pressure Relief Valve
Lead free Isolation valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi. (1953 Compliant)